The Low Voltage Directive (LVD), Directive 2014/35/EU, is the EU’s electrical safety law for equipment designed for use with a voltage rating between 50 and 1,000 V AC (alternating current) or between 75 and 1,500 V DC (direct current). Annex II excludes nine kinds of equipment, and radio equipment and most machinery are declared under their own law instead.
Key points
- Voltage range: the LVD covers electrical equipment rated 50 to 1,000 V AC or 75 to 1,500 V DC, and “low” refers to the top of that range. Battery packs and extra-low-voltage products below 50 V AC or 75 V DC are outside it.
- Exclusions: Annex II excludes nine items whatever their voltage, including equipment for explosive atmospheres, medical equipment and electricity meters.
- Radio equipment and machinery: being inside the voltage range does not always mean you declare against the LVD. These products take on its safety objectives, but you declare conformity under their own law.
- Self-assessment: where the LVD is the act you declare against, you assess the product yourself with no notified body, sign an EU declaration of conformity and affix the CE marking.
What is the Low Voltage Directive?
The Low Voltage Directive is the EU’s electrical safety law for equipment placed on the market. Its purpose is “a high level of protection of health and safety of persons, and of domestic animals and property.”[1]
It is a CE marking directive: equipment in scope carries the CE marking, the manufacturer’s sign that the product meets the EU law that applies to it. Equipment in scope may be made available only if it is built to good engineering practice in safety matters and does not endanger people, animals or property when properly installed, maintained and used as intended.[1]
Directive 2014/35/EU replaced Directive 2006/95/EC with effect from April 20, 2016.[1]
What are the Low Voltage Directive voltage limits?
The LVD applies to electrical equipment “designed for use with a voltage rating” of 50 to 1,000 V AC or 75 to 1,500 V DC, so equipment rated below 50 V AC or 75 V DC is outside it.[1]
The “low” refers to the top of that range, not to small voltages. Most battery products sit below the lower limit, which puts an 18 V cordless tool, for example, outside the Directive.
The Directive does not define “voltage rating”, though the rating is typically among the essential characteristics you are required to mark on the equipment.[1] The Commission’s LVD guidelines explain how the Commission reads the Directive, but they are guidance, not law.
How do you check whether the LVD applies to your product?
Run three checks on every product in your catalogue that has an electrical connection, because the LVD is the act you declare against only if the product clears all three.
- Read the rating. Is the product designed for use with a voltage rating of 50 to 1,000 V AC or 75 to 1,500 V DC? If not, the LVD does not apply.
- Check Annex II. Is the product one of the nine excluded items? If so, the LVD does not apply, whatever the voltage.
- Check for a more specific act. Radio equipment and machinery sit on top of the LVD and are declared under their own law, while toys are capped below the LVD’s range.
Do the checks one product at a time, not once for a product family: adding a Bluetooth module to a 12 V product, for instance, brings in electrical safety requirements the LVD never applied to it. Daptic works out which of these acts applies to each product you sell, market by market, and flags the regulatory changes that affect it.
What products are excluded from the Low Voltage Directive?
Annex II of the LVD excludes nine items whatever their voltage, and the table lists each one with its Annex II wording, abridged.
| Exclusion | Annex II wording (abridged) |
|---|---|
| Explosive atmospheres | Electrical equipment for use in an explosive atmosphere |
| Medical and radiology | Electrical equipment for radiology and medical purposes |
| Lifts | Electrical parts for goods and passenger lifts |
| Meters | Electricity meters |
| Domestic plugs and sockets | Plugs and socket outlets for domestic use |
| Fence controllers | Electric fence controllers |
| Interference | Radio-electrical interference |
| Ships, aircraft and railways | Specialised electrical equipment for ships, aircraft or railways that complies with safety provisions drawn up by international bodies in which the Member States participate |
| Evaluation kits | Custom-built evaluation kits for professionals, used solely at research and development facilities |
Each exclusion covers only what its exact words say:
- Medical: “medical purposes” does not cover a wellness gadget.
- Ships, aircraft and railways: the exclusion applies only to specialised equipment that meets the international safety provisions, so a standard kettle in a train galley is still a kettle.
- Interference: radio-electrical interference is a phenomenon, not a product.
- Meters: for active energy meters for residential, commercial and light industrial use, the Measuring Instruments Directive 2014/32/EU usually applies instead.[2]
When do radio equipment, machinery and toys fall under other laws?
Radio equipment and machinery take on the LVD’s safety objectives, but you declare conformity under their own law. Toys are capped below the LVD’s lower limit, so toy law governs their electrical safety.
Radio equipment
Radio equipment within the Radio Equipment Directive (RED), Directive 2014/53/EU, is “not … subject to Directive 2014/35/EU” except through RED Article 3(1)(a),[3] which imposes the LVD’s safety objectives “with no voltage limit applying.”
A 12 V product with a Bluetooth module therefore has to meet electrical safety objectives that the LVD never applied to it, and its declaration cites RED, not the LVD.
Machinery
The Machinery Directive 2006/42/EC and the Machinery Regulation (EU) 2023/1230 apply the LVD’s safety objectives to machinery.[4, 5] Conformity assessment and placing on the market for electrical risks are then “governed solely” by machinery law.
Machinery law leaves some electrical products out, and these stay with the LVD:[4, 5]
- household appliances, other than electrically operated furniture
- audiovisual and information technology (IT) equipment
- ordinary office machinery
- low-voltage switchgear and control gear
- electric motors
The Regulation, already adopted, replaces the Directive on January 20, 2027.
Toys
Under Directive 2009/48/EC on the safety of toys, a toy may not be powered above 24 V DC or the equivalent AC voltage.[6] That puts the toy below the LVD’s lower limit, so toy law governs its electrical safety.
“Electrical transformers for toys” are not toys,[6] so a transformer that takes 230 V AC in is LVD equipment. Regulation (EU) 2025/2509, already adopted, replaces the toy Directive from August 1, 2030.
What applies to products below the LVD voltage limits?
Products below 50 V AC or 75 V DC are outside the LVD, but other rules may still apply, depending on what the product is and who buys it.
- General Product Safety Regulation (GPSR): Regulation (EU) 2023/988 is the safety net for consumer products with no specific EU safety rules.[7] It has applied since December 13, 2024, and covers products intended for consumers or likely to be used by them.[7]
- Electromagnetic compatibility (EMC) Directive: it has no voltage limit, so it still applies to apparatus below the LVD range.
- RED or toy law: a radio function or a toy brings in those acts, as above.
A professional-only extra-low-voltage product that is neither machinery nor radio equipment may have no EU safety act at all, so check national rules.
What do manufacturers have to do under the LVD?
If the LVD is the act you declare against, you assess the product yourself under internal production control, also called Module A.[1] There is no role for a notified body, the independent assessor some EU laws require.
What safety objectives does Annex I set?
Annex I sets outcomes, not test methods. In plain terms:
- General conditions: mark the essential characteristics on the equipment (or on an accompanying document if that isn’t possible), make sure it can be assembled and connected safely, and design it against the hazards below.
- Hazards from the equipment: shock from direct or indirect contact, dangerous temperatures, arcs or radiation, non-electrical dangers that experience shows it can cause, and insulation suited to foreseeable conditions.
- External influences: enough mechanical strength, resistance to non-mechanical environmental conditions, and no danger under foreseeable overload.
Steps to the CE marking
- Design: make sure the design of the equipment meets the Annex I safety objectives.
- Technical file: draw up the technical documentation.
- Declaration: sign an EU declaration of conformity stating that the Annex I safety objectives are met.[1]
- CE marking: affix the CE marking to the equipment or its data plate.[1]
- Records: keep the technical documentation and the declaration for 10 years after placing on the market.[1]
Harmonised standards and the presumption of conformity
Applying harmonised standards cited in the Official Journal of the EU gives a presumption of conformity: the equipment is presumed to meet the safety objectives those standards cover.[1] The current list is Implementing Decision (EU) 2023/2723, last amended by Implementing Decision (EU) 2025/1488 of July 22, 2025.
Where no harmonised standard exists, the Directive falls back first to the safety provisions of the International Electrotechnical Commission (IEC),[1] then to national standards of the Member State of manufacture.[1]
Is the Low Voltage Directive changing?
The scope rules sit in the Directive itself, while the working detail moves through other instruments. An amendment known as Omnibus IV has been agreed in negotiations but not yet adopted.
- Harmonised standards: since its adoption, the list in Implementing Decision (EU) 2023/2723 has been amended four times, twice in 2024 and twice in 2025. Each amendment changes which standards give a presumption of conformity.
- Omnibus IV: on May 21, 2025, the Commission proposed amending the LVD and 11 other directives (procedure 2025/0133(COD)). On June 26, 2026, the European Parliament and the Council agreed a text in negotiations. A vote of the full Parliament is indicatively set for November 23, 2026, and neither institution has formally adopted it. As proposed, it would require the declaration of conformity in electronic form and allow electronic instructions, with safety information still on paper or on the product for consumer equipment. It would also add a digital contact point and allow Commission common specifications where no harmonised standard exists.[1]
- Neighbouring acts: from January 20, 2027, the Machinery Regulation replaces the Machinery Directive, and from August 1, 2030, the Toy Safety Regulation replaces the toy Directive. Both change where the LVD’s edges sit.
- Guidance: the Commission’s LVD guidelines and its July 2021 evaluation explain how the Commission reads the Directive, but they are guidance, not law.
Frequently asked questions
What voltage does the Low Voltage Directive cover?
The LVD covers electrical equipment designed for use with a voltage rating of 50 to 1,000 V AC or 75 to 1,500 V DC, so equipment rated below 50 V AC or 75 V DC is outside it.[1]
Does the Low Voltage Directive apply to battery-powered products?
Usually not: most battery products are below the LVD’s lower limit of 50 V AC or 75 V DC. The GPSR, the EMC Directive, RED or toy law may still apply, depending on what the product is and who buys it.
What products are excluded from the Low Voltage Directive?
Annex II excludes nine items whatever their voltage, including equipment for explosive atmospheres, radiology and medical equipment, electrical parts for lifts, electricity meters, domestic plugs and socket outlets, and electric fence controllers. The full list is in the table above.
Do you need a notified body for the Low Voltage Directive?
No. The LVD uses internal production control, also called Module A, so the manufacturer draws up the technical documentation, signs the EU declaration of conformity and affixes the CE marking without a notified body.[1]
Does the LVD apply to products with Bluetooth?
No. Radio equipment is declared under the Radio Equipment Directive 2014/53/EU, which applies the LVD’s safety objectives with no voltage limit, so a 12 V product with a Bluetooth module has to meet them too.
How long do you keep LVD documentation?
Keep both the technical documentation and the EU declaration of conformity for 10 years after the equipment is placed on the market.[1]
Notes and sources
- Directive 2014/35/EU (LVD): Articles 1, 3, 6, 12 to 15, 17, 27, 28; Annexes I, II, III
- Directive 2014/32/EU: Annex V (MI-003)
- Directive 2014/53/EU (RED): Articles 1(4), 3(1)(a)
- Directive 2006/42/EC, consolidated: Article 1(2)(k), Annex I point 1.5.1
- Regulation (EU) 2023/1230: Article 2(2)(p), Annex III point 1.5.1
- Directive 2009/48/EC: Annex I item 18, Annex II Part IV point 1; Regulation (EU) 2025/2509
- Regulation (EU) 2023/988 (GPSR): Articles 2(1), 3(1), 52
Additional sources:
- Commission LVD page and LVD harmonised standards page
- COM(2025) 503, Omnibus IV directive proposal: Article 10; Legislative Observatory, 2025/0133(COD))
- Last reviewed: November 9, 2026
This article reflects Marc Haddad’s independent opinions, not necessarily those of Daptic.